XT-W™ Welded Cassette Rupture Disk

Performance Features

  • Solid metal construction
  • 'X' shaped score pattern – designed for non-fragmentation & excellent for relief valve isolation
  • Smooth disk surface on process side – resistant to product accumulation
  • Designed for gas service or liquid service
  • High flow capacity/low flow resistance: Krg and Krl of 0.5 and high flow area in all sizes
  • Fail safe damage safety ratio < 1
  • Vacuum resistant; no additional support required

Request a Quote

 

  • Sizes & Pressures
  • Burst Tolerance
  • Accessories
  • Documentation

Sizes & Pressures

XT-W™ Positive Pressure Disk Specifications Minimum/Maximum Pressure with Rating at 72° (22°C) & Assembly Dimensions
Disk Size Burst Pressure [ØA] [ØB] [ØC] [D] ASME EN JIS BS
psig barg
in mm min max min max
1 25 15 70 1.03 4.82 [35] [31] [56.9] [42] 150/300/600 10/16/25/40 10/16/20/30/40 10
1.5 40 6 55 0.41 3.79 [48] [43.5] [76] [46] 150/300/600 10/16/25/40 10/16/20/30/40 10
2 50 5 40 0.34 2.76 [63.5] [59] [95] [50] 150/300/600 10/16/25/40 10/16/20/30/40 -
3 80 5 35 0.34 2.41 [89] [84.6] [126.75] [58] 150/300/600 10/16/25/40 16/20/30/40 -
5 100 5 30 0.34 2.07 [114.5] [110] [162] [74] 150 10/16/25/40 10 -
6 150 5 25 0.34 1.72 [165.3] [161] [215.5] [96] 150 10/16/25/40 10 -

Burst Tolerance

Marked Burst Pressure Burst Tolerance
≤ 40 psig (2.76 barg) ± 2 psig (0.138 barg)
> 40 psig (2.76 barg) ± 5%

Accessories

BS&B supplies many of the Accessories required to safely and conveniently install our overpressure relief devices and complementary products. Through our professional team and global network of sales engineers and procurement personnel, we are able to provide the highest quality accessory products to meet your installation requirements.

Saf-T-Change Quick Disk Replacement (QDR)

After activation, the replacement disk is quickly slid into place. Saving hours of lost production due to blown rupture disks.

Tell-Tale Assemblies & Excess Flow Valves/Gauges

A gauge tap in the outlet flange of the safety head may be considered when the safety head is installed in a vertical position.

Spare Safety Heads & Cap Screws

Jackscrews

When activated, the jackscrews effectively separate the flanges, providing adequate clearance to remove or insert a safety head and external gaskets.

Lifting Lug Eye Bolts

Eye bolts are recommended when weight and/or accessibility is a factor in lifting safety heads.

Baffle Plate

When a safety head is free-vented to atmosphere, a baffle plate may be considered to disperse overpressure and absorb recoil.

Product Literature

Burst Alert Sensors
Detec Saf Alarm System - Burst Disk Monitor